SICK C2000標(biāo)準(zhǔn)安 全光幕C20E-060303A11,C20S-060103A11
Functions-Sender
Beam coding: |
|
|
|
Beam coding (delivery status): |
non-coded |
|
Configuration method: |
hard wired |
|
Extension connection: |
√
|
|
Safe SICK device communication via EFI/SDL: |
√
|
Functions-Receiver
Restart interlock: |
- |
External device monitoring (EDM): |
√ |
External device monitoring (delivery status): |
activated |
Beam coding: |
√ |
Beam coding (delivery status): |
non-coded |
Muting with: |
Flexi Classic, Flexi Soft |
Configuration method: |
hard wired |
Extension connection: |
- |
Safe SICK device communication via EFI/SDL: |
- |
Technical Data-Sender
Protective field height: |
600 mm |
|
|
Resolution: |
30 mm |
|
Scanning range from ... to: |
0 m ... 6 m |
|
Housing cross-section: |
34 mm x 29 mm |
|
Type: |
Type 2 (IEC 61496) |
|
Category: |
category 2 (EN ISO 13849) |
|
Test rate (internal test): |
13 /s (EN ISO 13849) 1) |
|
Maximum demand rate: |
8 /min (EN ISO 13849) 2) |
|
Performance level: |
PL c (EN ISO 13849) |
|
PFHd: |
2.2 * 1E-08 |
|
TM (mission time): |
20 a |
|
Supply voltage typical, from, to: |
24 V DC, 19.2 V DC, 28.8 V DC |
|
Maximum power consumption: |
6.2 W |
|
System connection: |
male connector M12, 8-pin |
|
Maximum connection cable cross-section: |
0.25 mm2 |
|
Wave length: |
950 nm |
|
Protection class: |
III |
|
Enclosure rating: |
IP 65 (EN 60529) |
|
Ambient operating temperature: |
0 °C ... 55 °C |
|
Vibration resistance (checked to): |
5 g (IEC 68-2-6) |
|
Oscillation frequency from ... to: |
10 Hz ... 55 Hz |
|
Shock resistance: |
10 g (EN 60068-2-29) |
|
Weight: |
0.65 kg |
1) Internal test. The test rate may not be exceeded if an external test is performed. 2) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out.
Technical Data-Receiver
Protective field height: |
600 mm |
|
|
Resolution: |
30 mm |
|
Housing cross-section: |
34 mm x 29 mm |
|
Type: |
Type 2 (IEC 61496) |
|
Category: |
category 2 (EN ISO 13849) |
|
Test rate (internal test): |
13 /s (EN ISO 13849) 1) |
|
Maximum demand rate: |
8 /min (EN ISO 13849) 2) |
|
Performance level: |
PL c (EN ISO 13849) |
|
PFHd: |
2.2 * 1E-08 |
|
TM (mission time): |
20 a |
|
Supply voltage typical, from, to: |
24 V DC, 19.2 V DC, 28.8 V DC |
|
Maximum power consumption: |
8 W |
|
Response time: |
10.5 ms |
|
Wave length: |
950 nm |
|
System connection: |
male connector M12, 8-pin |
|
Maximum connection cable cross-section: |
0.25 mm2 |
|
Protection class: |
III |
|
Enclosure rating: |
IP 65 (EN 60529) |
|
Ambient operating temperature: |
0 °C ... 55 °C |
|
Vibration resistance (checked to): |
5 g (IEC 68-2-6) |
|
Oscillation frequency from ... to: |
10 Hz ... 55 Hz |
|
Shock resistance: |
10 g (EN 60068-2-29) |
|
Weight: |
0.65 kg |
1) Internal test. The test rate may not be exceeded if an external test is performed. 2) Between two demands on a safety-related response of the device, at least 100 internal or external tests must be carried out.